TSS W sc Triclamp Suspended solids probe, stainless steel, wiper, ball valve fitting

TSS W sc Triclamp Suspended solids probe, stainless steel, wiper, ball valve fitting
Številka izdelka: LXV324.99.20001
Cena na enoto Kontakt
Odprema v 1 tednu

TSS sc probes have been specially developed for industrial applications

Turbidity from 0.001 - 4,000 FNU and suspended solids from 0.001 - 500 g/L

8 measurement signals cover the total range and deliver measured values in conformity with the relevant standards

Excellent stability thanks to comprehensive compensation for interference factors

TSS sc has a unique compensation system to overcome the effects of air bubbles

Vsebina paketa

Turbidity & Suspended Solids sensor, user manual

Specifikacije

Aplikacija: Standard
Avtomatsko čiščenje: Da
Delovna temperatura: 0 - 50 °C
Diameter: 40 mm
Dolžina: 332 mm
Dolžina kabla: 10 m (optional extension cables available)
Garancija: 24 mesecev
Konfiguracija montaže: TriClamp
Maksimalna temperatura: 50 °C
Material: Gasket: FKM; Wiper: PA (GF), TPV
Merilna metoda: Combined multiple beam alternating
light method with infrared diode
system and beam focussing
Turbidity (TRB): 2-channel 90° scattered light measurement
in accordance with DIN/EN 27027/ISO 7027,
wavelength = 860 nm
Solids (TSS): 120° scattered light measurement,
wavelength = 860 nm
Merilno območje: 0,001 - 500 g/L
  0,001 - 9999 FNU
  Turbidity (TRB): 0.001 - 9999 NTU
Solids (TSS): 0.001 - 500 g/L
Model: TSS W sc
Način montaže: Weld On TriClamp Fitting
Natančnost: Turbidity Up to 1000 FNU/NTU: < 5 % of the measured value ±0.01 NTU
Območje tlaka: < 6 bar or < 60 m
Odzivni čas T90: 1 - 300 s adjustable
Parameter: Turbidity, Suspended Solids
Ponovljivost: TSS content: < 4 %
Turbidity: < 3 %
Posebna značilnost: With Wiper & Triclamp
Posebni zapiski: Installation note:
Distance sensor–wall
> 50 cm (Turbidity)
> 10 cm (TSS)
Pretok: Max. 3 m/s (the presence of air bubbles affects the measurement)
Servisni interval: 1 h/mesec
Temperatura okolja: 0 - 60 °C (briefly 80 °C)
Teža: Approx. 1.6 kg
Umeritev: Turbidity (TRB): Factory calibrated
Solids (TS): To be calibrated by customer on site
Zero point: Permanently calibrated in the factory
Umertivena metoda: Turbidity: Formazin or Stablcal Standard (at 800 NTU). Requires a calibration kit.
Suspended Solids: Sample specific, based on gravimetric analysis with a correction factor procedure.
Vsebina paketa: Turbidity & Suspended Solids sensor, user manual
Združljivost kontrolnih enot: SC200, SC1000, SC4500. All controllers sold separately