TSS EX1 sc Inline suspended solids probe, stainless steel, ATEX

TSS EX1 sc Inline suspended solids probe, stainless steel, ATEX
Številka izdelka: LXV328.99.30001
Cena na enoto Kontakt
Odprema v 2 tednih

TSS sc probes have been specially developed for industrial applications

Measures both turbidity and suspended solids

8 measurement signals cover the total range and deliver measured values in conformity with the relevant standards

Excellent stability thanks to comprehensive compensation for interference factors

TSS sc has a unique compensation system to overcome the effects of air bubbles

Vsebina paketa

Turbidity & Suspended Solids sensor, user manual

Specifikacije

Aplikacija: Hazardous locations
Avtomatsko čiščenje: Ne
Delovna temperatura: -10 - 50 °C
Diameter: 48.5 mm
Dolžina: 488 mm
Dolžina kabla: 10 m
Garancija: 24 mesecev
Konfiguracija montaže: Insertion
Maksimalna temperatura: 50 °C
Material: Optics Carrier and Sleeve: stainless steel 1.4460 / stainless steel 1.4404; Wiper Arm: stainless steel 1.4581; Wiper Rubber: silicone rubber (standard) Optional: FKM/FPM (LZX578); Wiper Shaft: stainless steel 1.4104
Merilna metoda: Combined multiple beam alternating light method with infrared diode system and beam focusing
Turbidity (TRB): 2-channel 90º scattered light measurement in accordance with DIN EN ISO 7027, wavelength = 860 nm
Solids (TS): 90º and 120º scattered light measurement, wavelength = 860 nm
Merilno območje: 0,001 - 4000 FNU
  0,001 - 500 g/L
  Turbidity (TRB): 0.001 - 9999 NTU
Solids (TSS): 0.001 - 500 g/L
Model: TSS EX1 sc
Način montaže: Ball Valve Insertion
Natančnost: Turbidity up to 1000 FNU/NTU: < 5 % of measurement value or ±0.01 NTU, whichever is greater
Območje tlaka: 10 bar or 100 m
Odzivni čas T90: 1 - 300 s adjustable
Parameter: Turbidity, Suspended Solids
Ponovljivost: TSS content: < 4 %
Turbidity: < 3 %
Posebna značilnost: Simple Inline installation
Posebni zapiski: Installation note:
Distance sensor–wall
> 50 cm (Turbidity)
> 10 cm (TSS)
Pretok: Max. 3 m/s (the presence of air bubbles affects the measurement)
Servisni interval: 1 h/mesec
Temperatura okolja: 0 - 50 °C
Teža: approx. 2.7 kg
Umeritev: Turbidity (TRB): Factory calibrated
Solids (TS): To be calibrated by customer on site
Zero point: Permanently calibrated in the factory
Umertivena metoda: Turbidity: Formazin or Stablcal Standard (at 800 NTU). Requires a calibration kit.
Suspended Solids: Sample specific, based on gravimetric analysis with a correction factor procedure.
Vsebina paketa: Turbidity & Suspended Solids sensor, user manual
Združljivost kontrolnih enot: SC200, SC1000, SC4500. All controllers sold separately