Analogni izhodi:
Active 0 - 20 mA (or 4 - 20 mA) max. 500 Ohm load, standard: 4, optional: 8
Avtomatsko čiščenje:
Yes; Frequency freely programmable: 6 hours, 12 hours, daily, weekly
Certificiranje:
CE, ETL certified to UL and CSA safety standards, UKCA
Demineralised water:
Internal dilution option: Rinse water & Dilution water
Digital outputs:
Profibus DP or Modbus RTU
Dimenzija (v x š x g):
688 mm x 460 mm x 340 mm
Earth connection:
Dry and clean earth pole with low impedance (< 1 Ohm) using an earth cable of > 2.5 mm²
Garancija:
24 mesecev
Instrument air:
Dry and oil free according to ISA-S7.0.01-1996 quality standard for instrument air. Used to flush the instrument in corrosive environement. Min. 0.2 bar - Max. 0.5 bar
Interference :
Positive interferences may be caused by arsenate (AsO₄³⁻) and, under heated conditions, by silica or silicate (SiO₄-)
Reducing substances such as sulfide (S²⁻), thiosulfate (S₂O₃²⁻), thiocyanate (SCN⁻), and excess molybdate (MoO₄²⁻) may interfere at high concentrations. The following ions do not cause interference at concentrations up to 1,000 mg/L: aluminium, ferric iron, magnesium, calcium, barium, strontium, lithium, sodium, potassium, ammonium, cadmium(II), manganese(II), lead(II), mercury(I), mercury(II), tin(II), copper, nickel, silver(I), uranium(IV), zirconium(IV), arsenite, bromide, carbonate, perchlorate, cyanide, iodate, nitrate, nitrite, sulfate, sulfite, pyrophosphate, tetraborate, selenate, benzoate, citrate, oxalate, lactate, tartrate, formate, and salicylate.
Large quantities of color and turbidity interfere. Fats, oil, proteins, surfactants and tar interfere.
Izhod:
Optional: Claros Ethernet connection and Modbus TCP/IP Ethernet connector; LAN version; 10/100 Mbps or Profinet or Ethernet IP
Kakovost vzorca:
Maximum particle size 100 µm, < 0.1 g/L; Turbidity < 50 NTU
Kiveta za vzorec:
No Dilution
Default: 10 min.
Continuous: 9 min.
Internal Dilution
Default: 15 min.
Continuous: 12 min.
Material:
Hinged part: Thermoform ABS, door: PMMA
Wall section: Galvanised steel, powder coated
Meja zaznavanja:
No Dilution
0.02 - 1 mg/L PO₄-P: 0.02 mg/L
0.05 - 2.5 mg/L PO₄-P: 0.05 mg/L
0.05 - 5 mg/L PO₄-P: 0.05 mg/L
0.1 - 10 mg/L PO₄-P: 0.1 mg/L
Internal Dilution
0.5 - 50 mg/L PO₄-P: 0.5 mg/L
1 - 100 mg/L PO₄-P: 1 mg/L
2.5 - 250 mg/L PO₄-P: 2.5 mg/L
5 - 500 mg/L PO₄-P: 5 mg/L
7.5 - 750 mg/L PO₄-P: 7.5 mg/L
10 - 1000 mg/L PO₄-P: 10 mg/L
Merilna metoda:
Colorimetric measurement vanadates yellow method compliant with APHA 4500-P (C)
Merilno območje:
No Dilution
0.02 - 1 mg/L PO₄-P
0.05 - 2.5 mg/L PO₄-P
0.05 - 5 mg/L PO₄-P
0.1 - 10 mg/L PO₄-P
Internal Dilution
0.5 - 50 mg/L PO₄-P
1 - 100 mg/L PO₄-P
2.5 - 250 mg/L PO₄-P
5 - 500 mg/L PO₄-P
7.5 - 750 mg/L PO₄-P
10 - 1000 mg/L PO₄-P
Moč:
100 - 240 VAC, 50/60 Hz
Max. power consumption: 120 VA
Odvod:
Atmospheric pressure, vented, min. Ø 32 mm
Parameter:
Phosphate (vanadate yellow)
Precision:
Better than 2% full scale range for standard test solutions
Pretok vzorca:
100 - 300 mL/min
Razred zaščite:
IP44
Reagent Requirements:
Keep between 10 - 30 °C
Releji:
5 contacts, not user configurable: Malfuntion, maintenance, analysis ready, sample ready, sample ready (EZ9150)
Št. vzorca:
Standard: 1
Optional accessory for 2, 4, or 8 sample streams
Temperatura okolja:
10 - 30 °C ± 4 °C deviation at 5 - 95% relative humidity (non-condensing)
Temperatura vzorca:
5 - 30 °C
Teža:
Max. 35 kg
Umeritev:
Automatic; 2-point; offset or slope; Frequency freely programmable: 6 hours, 12 hours, daily, weekly. Note: manufacturer recommends that a calibration is done when the reagents are replaced
Validation:
Automatic; Frequency freely programmable: 6 hours, 12 hours, daily, weekly
Vsebina paketa:
EZ1031sc Phosphate Analyser, Instruction Manual, 1 x Double Bit Door Key, 1 x Mounting Brackets and 1 x empty 2.5L Reagent Container with Fittings (for Colour Solution)
Vzorec: tlak:
By external overflow vessel (open to atmospheric pressure)